You create a DCS by using a wizard or a preconfigured XML template. The data can be a single performance log, event trace, or system configuration data set, or any combination of the three. You can also configure Performance Counter Alerts from this interface.

To create a new DCS, follow these steps:

1.
Open the Reliability And Performance Monitor and select the User Defined node beneath the Data Collector Sets node.

2.
Right-click the User Defined node, select New, and then select Data Collector Set to start the Create New Data Collector Set Wizard.

3.
Provide a name for the data collector set and choose to create from a template or create manually by following the remaining steps of the wizard.

When you create a new DCS, it is simplest to use the Create From A Template option in the Data Collector Set Wizard. You can create templates for common monitoring scenarios and use them to quickly configure and start a new logging session using the template settings. The templates are in XML format; all settings for the DCS are specified in the template. Windows Vista includes three preconfigured templates for creating new Data Collector Sets:

  • Basic

  • System Diagnostics

  • System Performance

You can also export a DCS as a template that can be modified and imported to create new Data Collector Sets. To export a DCS configuration XML file, right-click the Data Collector Set name in the Data Collector Sets node in System Monitor and then select Export Settings from the shortcut menu. The template files are not saved to a template store; you must import them each time you use them. You can save the XML template files to any folder you have access to.

Generally, a template is exported from a manually configured DCS. After you export the DCS template, you can edit the template to customize it for particular scenarios (different computer, different folder, and so on). After you have exported the template, you can import it into the DCS by selecting Create From A Template in the Create New Data Collector Set wizard and browsing to the location of the XML file.

Note

Performance Monitor no longer installs a default System Overview log. However, it does provide a System Diagnostics Data Collector Set template.


To manually create a DCS, follow these steps:

1.
In the Create New Data Collector Set Wizard, select Create Manually and then click Next.

2.
Select the desired data collector(s) and then click Next.

3.
Select the performance counters, if any, that will be collected in the data collector and then click Next.

4.
Select the event trace providers, if any, that will be used and then click Next.

5.
Select registry keys to be monitored, if any, and then click Next.

6.
Choose the path to the DCS and then click Next. All of the data files for the DCS will use this path and will share the parent folder that you specify. The default path for data collector sets is %SystemDrive%\perflogs\<Data Collector Set name>.

7.
Click Change and then select the user account that will run this data collector set.

8.
Before completing the wizard, you can select options to open the properties of the data set when completing the wizard and start the data collection immediately after completing the wizard.

9.
Click Finish to display the DCS in the Reliability and Performance Monitor. You can view the status of all of the configured Data Collector Sets by selecting the desired parent node under the Data Collector Sets node.

10.
To view the data collector(s) contained within a DCS in the Reliability and Performance Monitor, expand the User Defined node in the left pane. Then, either click the Data Collector Set name under the User Defined node or double-click the Data Collector Set name if it appears in the right-hand pane.

To start the Data Collector Set, click to highlight the DCS name and either click the green arrow on the toolbar to start logging or right-click the Data Collector Set name and then select Start from the shortcut menu.

Configuring a Data Collector Set

To access the properties for a DCS, right-click the Data Collector Set’s name and select Properties from the shortcut menu. All of the properties for a data collector are configured from this interface. Properties available on each tab are:

  • General Tab Configure the data collector description, any keywords that are desired for Search purposes, and the Run As properties that determine under what user context this DCS will run. Click Change to change the user context for the collector. The default is the Local System account.

  • Directory Tab Configure the root directory for the DCS and specify a separate subdirectory if desired. The default is %SystemDrive%\perflogs\<Data Collector Set name>. You can also specify the format of the subdirectory name based on the following options:

    • Date and time Choose from the available subdirectory name formatting options that are displayed.

    • Computer name The subdirectory can also be prefixed with the computer name, if desired, by selecting the Prefix Subdirectory With Computer Name check box.

    • Serial Number You can use the Serial Number format (N) to create a unique subfolder name each time the DCS is started. This allows multiple logs of the same data collectors to be saved within different subfolders in the parent DCS folder. You can edit the serial only in the Data Collector Set Properties, but the serial number format may also be specified to be used by individual data collectors. The default DCS subdirectory naming convention is NNNNNN, which results in Data Collector Set subfolders named 00000x (where x is the serial number).

      For example, a Data Collector Set with a serial number of 8 run on January 31, 2003 at 4:20 a.m. would have the following results based on the selected subdirectory name format:

      • Subdirectory name format: yyyyMMddNNNN; Actual subdirectory name: 200301310008

      • Subdirectory name format: yyDDD NN; Actual subdirectory name: 03031 08

      • Subdirectory name format: MMMM MM\, yyyy \a\t h mmtt \- N; Actual subdirectory name: January 31, 2003 at 4 20 AM – 8

  • Security Tab Specific security parameters on the DCS. Default permissions are granted to SYSTEM, Administrators, Performance Log Users, and the data collector creator/owner.

  • Schedule Tab Configure the beginning date, expiration date, and launch time and day. Click Add to configure a schedule.

  • Stop Condition Tab Defines when the data collection will stop. Options available on this tab include:

    • Overall Duration Configures the log to stop after a defined duration in seconds, minutes, days, hours, or weeks.

    • Limits Defines limits for the log size or duration and whether to restart the Data Collector Set when those limits are reached. You can set the time duration or maximum size limit.

  • Task Tab Allows configuration of a specific task to run when a Data Collector Set stops. The specified task must be an existing Task Scheduler task. You can also specify the task arguments and the working directory.

Note

You can also view and edit the properties of each data collector within a DCS by using the shortcut menus for each data collector. The configuration settings for a data collector vary depending on whether the data collector is used for collecting performance counter, event tracing, or registry information.

Other -----------------
- Preparing Windows PE : Automating Windows PE, Using Windows PE with BDD
- Using Voice and Sounds : Customizing Speech Recognition, Talking to the Mouse
- Using Voice and Sounds : Directing Your Computer with Voice Commands, Dictating Text
- Using Voice and Sounds : Controlling the Volume
- Preparing Windows PE : Working with Windows PE (part 3) - Customizing Windows PE
- Preparing Windows PE : Working with Windows PE (part 2)
- Preparing Windows PE : Working with Windows PE (part 1) - Adding Optional Components
- Maintaining Security : Restricting Content in Windows Media Center, Creating Trusted Contacts, Installing Critical Fixes
- Maintaining Security : Restricting Content in Windows Media Center, Creating Trusted Contacts
- Maintaining Security : Restricting DVD Movies in Windows Media Player, Preventing Access While Using Windows Media Player
 
 
Top 10
- Microsoft Visio 2013 : Adding Structure to Your Diagrams - Finding containers and lists in Visio (part 2) - Wireframes,Legends
- Microsoft Visio 2013 : Adding Structure to Your Diagrams - Finding containers and lists in Visio (part 1) - Swimlanes
- Microsoft Visio 2013 : Adding Structure to Your Diagrams - Formatting and sizing lists
- Microsoft Visio 2013 : Adding Structure to Your Diagrams - Adding shapes to lists
- Microsoft Visio 2013 : Adding Structure to Your Diagrams - Sizing containers
- Microsoft Access 2010 : Control Properties and Why to Use Them (part 3) - The Other Properties of a Control
- Microsoft Access 2010 : Control Properties and Why to Use Them (part 2) - The Data Properties of a Control
- Microsoft Access 2010 : Control Properties and Why to Use Them (part 1) - The Format Properties of a Control
- Microsoft Access 2010 : Form Properties and Why Should You Use Them - Working with the Properties Window
- Microsoft Visio 2013 : Using the Organization Chart Wizard with new data
 
programming4us
Windows Vista
programming4us
Windows 7
programming4us
Windows Azure
programming4us
Windows Server